Scheu Products Company 30-FAS/SPC-30 Betriebsanleitung

Stöbern Sie online oder laden Sie Betriebsanleitung nach Raumheizungen Scheu Products Company 30-FAS/SPC-30 herunter. Scheu Products Company 30-FAS/SPC-30 Operating instructions Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 4
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
OPERATING INFORMATION
SCHEU PRODUCTS COMPANY, INCORPORATED
Mail: P.O. Box 5050, Upland, CA 91785-5050
Plant: 8855 Baker Ave., Rancho Cucamonga, CA 91730
TELEPHONE: 909 981-5343
ASSEMBLY AND OPERATING INSTRUCTIONS
UNIVERSAL MODELS 12-IR, 24-IR, 24-IRP, 36-IR, 48-IR
ALL PRO MODELS SPC-12, SPC-24, SPC-24P, SPC-36, SPC-48
INFRA-RED HEATERS
1. Check the heater thoroughly for damage. DO NOT operate a
damaged heater.
2. Do not modify the heater or operate a heater which has
been modified from its original condition.
3. Use only propane gas.
4. Use only VAPOR WITHDRAWAL propane cylinders. If there
is any question about vapor withdrawal, ask your propane
dealer.
5. Mount propane cylinders vertically (shutoff valve up). Secure
them from falling or being knocked over and protect them
fromdamage.
6. Do not direct heat toward propane cylinders.
7. Use only the hose and regulator assembly provided with the
heater. Inspect hose assembly before each use of the
heater. If there is excessive abrasion or wear, or hose is
cut, replace with hose assembly listed on parts list before
using heater. The hose and fittings shall be protected
from damage and deterioration.
8. For indoor or outdoor use. AREA MUST BE WELL VENTI-
LATED. Provide minimum openings of 1 sq. ft. near the floor
and 1 sq. ft. near the ceiling (also see "Operating Informa-
tion").
9. If at any time gas odor is detected, IMMEDIATELY DISCON-
TINUE operation until the source of gas has been located
and corrected.
10. Install the heater such that it is not directly exposed to water
spray, rain, dripping water and/or wind.
11. Maintain minimum clearance from normal combustible
materials (like paper) as follows: rear-2 ft.; sides-3 ft.;
front-6 ft. Locate 10 ft. from canvas or plastic tarpaulins or
similar coverings and secure them to prevent flapping or
movement due to wind action.
12. Operate only on a stable, level surface.
13. Since permanent skin tissue damage can occur, avoid
contact with the unit while it is operating or shortly after it
has been shut off.
14. Operate the unit in a draft-free area or protect the heater
fromdrafts.
15. Do not move, handle or service while hot or burning.
16. Use only in accordance with local codes or, in the absence
of local codes, with the Standard for the Storage and
Handling of Liquefied Petroleum Gases ANSI/NFPA 58-
1998, and National Fuel Gas Code ANSI Z223.1/NFPA
TYPE OF GAS...........................For use with Propane Only
INPUT RATING....................................12-IR 11,000 BTU/hr
.............................24-IR/24-IRP 22,000 BTU/hr
........................................36-IR 33,000 BTU/hr
........................................48-IR 44,000 BTU/hr
MANIFOLD PRESSURE..........................28" Water Column
ORIFICE SIZE....................................................No. 69 Drill
This is a propane, direct-fired, heater. It's intended use is
primarily temporary heating of buildings under construction,
alteration or repair.
WARNING:
NOT FOR HOME OR RECREATIONAL VEHICLE USE
Propane is heavier than air. If propane leaks from a connec-
tion or fitting, it sinks to the floor, collecting there with the
surrounding air, forming a potentially explosive mixture.
Obviously, propane leaks should be avoided, so set up the
propane supply with utmost care. Leak check new connec-
tions or reconnections with a soap and water solution and
follow all connection instructions herein. Also ask your
propane dealer for advice on the propane supply installation
and ask him to check it if there are any questions.
Direct-fired means that all of the combustion products from
burning propane enter the heated space. Even though this
heater operates very close to 100 percent combustion effi-
ciency, it still produces small amounts of carbon monoxide.
Carbon monoxide (called CO) is toxic.
CO can build up in a heated space and failure to provide
adequate ventilation could result in death. The symptoms of
inadequate ventilation are:
headache
dizziness
burning eyes and nose
nausea
dry mouth or sore throat
So, be sure to follow advice about VENTILATION in these
operating instructions.
!
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUC-
TIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH,
SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE
FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION,
AND CARBON MONOXIDE POISONING.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE
INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS
AN INSTRUCTIONS MANUAL, LABELS, ETC. CONTACT THE
MANUFACTURER.
SAFETY PRECAUTIONS
WARNING: Improper installation, alteration,
service or maintenance can cause property damage,
injury, or death. Read the installation operating and
maintenance instrucitons thoroughly before installing or
servicing this equipment.
!
!
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - SAFETY PRECAUTIONS

OPERATING INFORMATIONSCHEU PRODUCTS COMPANY, INCORPORATEDMail: P.O. Box 5050, Upland, CA 91785-5050Plant: 8855 Baker Ave., Rancho Cucamonga, CA 91730

Seite 2 - OPERATING INSTRUCTIONS

START1. Fully open the valve on the propane cylinder.2. Depress the red button on the safety valve admitting gasto the heater. Place a lighted match

Seite 3

The heater should be serviced only by a trained, experiencedservice person.Read the section on "Servicing" before ordering parts.For parts o

Seite 4

SEPTEMBER 20006326PPage 4MAINTENANCE AND STORAGE1. The heater should be inspected before each use, and atleast annually by a qualified person.2. Befor